Lithium Charging Instructions

Charging Instructions 09.02.20
CHARGING INSTRUCTIONS
relionbattery.com
+
1.803.547.7288
855.931.2466
© 2020 Relion Battery, LLC. All rights reserved. Relion Battery is not liable for damages that may result from any information provided in or omitted from this publication, under any circumstances. Relion Battery reserves the right to make adjustments to this publication at any time, without notice or obligation.
1433 Dave Lyle Blvd
Rock Hill, SC 29730, US
Engineered
in the USA
Charge Profiles
LiFePO batteries can be charged with either a 1-stage profile (constant current (CC) aka Bulk Stage) or a 2-stage profile (constant
current, constant voltage (CC-CV) profile aka Bulk and Absorption Stages). The 1-stage profile will charge the battery ~97% and
the 2-stage profile will charge the battery 100%. The 1-stage profile is suicient, since LiFePO batteries do not need to be fully
charged; this will not reduce life as it does with lead-acid.
1-Stage Charge Profile - CC
1-STEP CHARGE
DESCRIPTION
STEPS DESCRIPTION CHARGE PARAMETERS
Step 1 - Charge
at a constant
current until
the battery
reaches
termination
voltage.
1
*Recommended
Charge Current
≤0.5C (C = Capacity of battery system)
**Maximum
Charge Current
1C or 100A (the lower of the two values)
SYSTEM VOLTAGE 12V 24V 36V 48V
Stop
Termination
Voltage
14V – 14.6V 28V - 29.2V 42V - 43.8V 56V - 58.4V
2 Stage Charge Profile - CC-CV
2-STEP CHARGE
DESCRIPTION
STEPS DESCRIPTION CHARGE PARAMETERS
Step 1 - Charge
at a constant
current until
the battery
reaches
absorption
voltage.
1
*Recommended
Charge Current
≤0.5C (C = Capacity of battery system)
**Maximum
Charge Current
1C or 100A (the lower of the two values)
SYSTEM VOLTAGE 12V 24V 36V 48V
Step 2 - Hold
absorption
voltage until
charge reduces
to termination
current.
2
Absorption
Voltage
14V – 14.6V 28V - 29.2V 42V - 43.8V 56V - 58.4V
Stop
Termination
Current
≤0.05C (C = Capacity of battery system)
* Charge current must be reduced at temperatures <0C (32F). See details in Charge Temperature section.
** For optimum life, charge at recommended rate. Some models are specially designed to allow for higher current.