User's Manual

PRELIMINARY
PRELIMINARY PRELIMINARY
PRELIMINARY –
Service
ServiceService
Service Manual
Manual Manual
Manual
DR CHKD APPD
36
12
Reset scan mode
13
Scan priority
3 PC modify mode
Make settings through external programmer or PC program software:
1
Frequency stability
2
RF power
3
Low power alarm
4 Squelchlevel 9&3
5 CTCSS deviationWide/Narrow••
6
DQT deviation
W
ide/Narrow
••
7
Receive sensitivitylowmediumhigh
4 Wire Clone:
Press MONI to turn on the power , enter wire clone mode 2 seconds
later, press PTT,
Begin cloning while red lights, finish while light goes out.
5 Mode setting:
Short cut the SELF on PCB, and turn on the power till “BEEP”.
Set channel selector knob to corresponding place according to
the model1-16
Press [MONI]then press [PTT], to set the channel, channel data and
initial data.
Turn off the power, disconnect SELF on PCB to end mode settings.
Eg. RPV516A2, its serial number is 2, to initialize: short cut SELF on
PCB to turn on
The power, set channel selector knob at CH2, press MONI, then press
PTT, the initial data of 1-4 channel can be found in the diagram,
serial number 2. Reset data to initial data. The receive and transmit
frequency of channel 5-14 are the same with channel 1, signals are
channel5, 1067.0Hz6,11151.4Hz7,12250.3Hz8,13423DQT••9,14-
423DQT, Channel 1-9 are Wide , Channel 10-14 are NarrowTurn off
the power after reset, disconnecting SELF and restart the power to
use the transceiver.
Remarks:
The old data(frequency, CTCSS/DQT, channel function) will be deleted once set the new
mode by pressing MONI AND PTT , part of the function also would be changed. Therefore,
do not set this operation unless change the EEPROM, etc.