THE SMARTER WAY TO REDUCE EMISSIONS REMEHA CONDENSING BOILER RANGE The most efficient way to reduce your carbon footprint.
3 REMEHA GAS 310/610 ECO PRO OVERVIEW REMEHA GAS 310/610 ECO PRO OVERVIEW INTRODUCTION BOILER DESCRIPTION APPLICATION INFORMATION 60% of the buildings that will be standing in 2050 are already here with us today. So tomorrow, there will be a great need for intelligent heating technology specifically designed for refurbished buildings. This is where Remeha’s advanced thinking is leading the way.
4 5 REMEHA GAS 310/610 ECO PRO OVERVIEW REMEHA GAS 310/610 ECO PRO OVERVIEW TYPICAL REMEHA GAS 310 ECO PRO BOILER CONSTRUCTION TYPICAL REMEHA GAS 610 ECO PRO BOILER CONSTRUCTION The unit has been inspected for compliance with the essential requirements of the following directives: CE identification number (PIN): 0063CL3613 NOx Class: 5 The unit has been inspected for compliance with the essential requirements of the following directives: CE identification number (PIN): 0063CL3613 NOx Class: 5 1 Fl
6 7 REMEHA GAS 310/610 ECO PRO OVERVIEW REMEHA GAS 310/610 ECO PRO OVERVIEW OPERATING PRINCIPLE Combustion air is drawn into the inlet connection from the plant room (conventionally flued) or from outside via the eccentric flue system (room sealed) by an air supply fan. On the inlet side of the fan is a specially designed chamber (venturi unit) which takes gas from the multiblock and mixes it in the correct proportions with the incoming air.
8 9 REMEHA GAS 310/610 ECO PRO OVERVIEW REMEHA GAS 310 ECO PRO DIMENSIONS REMEHA GAS 310/610 ECO PRO OVERVIEW REMEHA GAS 610 ECO PRO DIMENSIONS C Ø 250 L 353 1460 592 722 353 592 2 920 8 155 65 310 447 366 130 65 1293 1310 Ø 250 2 320 1023 2 1477 80 1500 1726 8 641 B 353 A C 894,5 L 320 B 2 Heating circuit flow (80mm) ” ;” Flange NW 80 (Standard DIN 2576) Heating circuit flow (80mm) ” ;” Flange NW 80 (Standard DIN 2576) Heating circuit return (65mm) ” ;” Flange N
10 11 REMEHA GAS 310/610 ECO PRO OVERVIEW REMEHA GAS 310/610 ECO PRO OVERVIEW REMEHA GAS 310 ECO PRO DIMENSIONS REMEHA GAS 610 ECO PRO DIMENSIONS The service side with the inspection hatch on the heat exchanger is considered to be the front of the boiler. The Remeha Gas 310 ECO PRO boiler is available in both a left-hand and right-hand version. This means that the hydraulic connections and the flue gas discharge are situated on either the left or the right-hand side of the boiler.
12 13 REMEHA GAS 310/610 ECO PRO OVERVIEW MAINTENANCE AREAS C + 1100* 800* C + 600 Remeha Gas 310 ECO PRO C 300 For the dimensions of C/C1, see page 8 SINGLE GAS 310 ECO PRO Using the optional secondary return 300 800* C + 1100* REMEHA GAS 310/610 ECO PRO OVERVIEW 800* 720 High Temperature Flow Gas Low Temperature Flow 150 720 800* 3190* 300 720 1670* C 300 800* 150 C + 600 High Temperature Return Low Temperature Return C + C1 + 2200* 800* 800* C1 C 600 Condensate 300 720
14 15 REMEHA GAS 310/610 ECO PRO OVERVIEW REMEHA GAS 310 ECO PRO TECHNICAL DATA Remeha Gas 310 ECO PRO REMEHA GAS 310/610 ECO PRO OVERVIEW REMEHA GAS 610 ECO PRO TECHNICAL DATA 285 355 430 500 575 650 5 6 7 8 9 10 General Remeha Gas 610 ECO PRO 570 710 2x5 2x6 860 1000 1150 1300 2x7 2x8 2x9 2x10 148 1060 158 1202 General Number of sections - EC indentification no.
16 17 REMEHA GAS 310/610 ECO PRO OVERVIEW REMEHA GAS 310/610 ECO PRO OVERVIEW REMEHA GAS 310 ECO PRO FLUE DATA Open flue (B23, B23P) Connection in areas of different pressure (C53, C83) If using an open version, the air supply opening remains open; only the combustion gas opening is connected. The boiler then takes in the combustion air required directly from the premises in which it is installed.
18 19 REMEHA GAS 310/610 ECO PRO OVERVIEW REMEHA GAS 310/610 ECO PRO OVERVIEW REMEHA GAS 610 ECO PRO FLUE DATA Open flue (B23, B23P) Connection in areas of different pressure (C53, C83) If using an open version, the air supply opening remains open; only the combustion gas opening is connected. The boiler then takes in the combustion air required directly from the premises in which it is installed.
20 21 REMEHA GAS 310/610 ECO PRO OVERVIEW REMEHA GAS 310/610 ECO PRO OVERVIEW CONTROLS The Remeha Gas 310/610 ECO PRO boilers can be controlled using one of the following methods: NOTE: This applies to each module on the Remeha Gas 610 ECO PRO. 1. On/Off control GAS 310 ECO PRO (1 x NO VOLT FREE SWITCHED PAIR) The heat output modulated between the minimum and the maximum value based on the set flow temperature, connected to ON/OFF - OT on PCU-06. Please see page 24.
22 23 REMEHA GAS 310/610 ECO PRO OVERVIEW ELECTRICAL CONNECTIONS AND CONTROLS REMEHA GAS 310/610 ECO PRO The fan has Power Factor Control (PFC ensures that the mains supply is distributed more uniformly) and is fused with a 6.3 AT fuse Fb (next to the 230V terminal strip). GENERAL SPECIFICATIONS Automatic controls NOTE: General specifications apply to each boiler module on the Remeha Gas 610 ECO PRO. COMFORT MASTER The Remeha Gas 310/610 ECO PRO has a unique boiler code.
24 25 REMEHA GAS 310/610 ECO PRO OVERVIEW REMEHA GAS 310/610 ECO PRO OVERVIEW SAFETY INTERLOCKS PCU-06 X0 X0 X02 M Pump 1 2 3 1 2 3 X0 1 2 3 4 5 6 7 8 9 10 11 12 X05 X06 X07 1 10 1 2 3 4 1 2 3 N L Y GN BL BK BL BK BL BK OR H H OR BR Y H H R H BR BR BL N PSU T PS PC I L L X08 O OT X51 GB X09 X06 X08 X05 X04 1 2 3 4 SU-0 X09 BR H GN Y 1 5 4 2 X08 X02 X01 This applies to Remeha Gas 310 ECO PRO and each module on the Remeha Gas 610 ECO PRO As standard the boilers
26 27 REMEHA GAS 310/610 ECO PRO OVERVIEW REMEHA GAS 310/610 ECO PRO OVERVIEW External gas valve control Boiler pump control Frost protection If there is a heat demand, an alternating voltage of 230 VAC, 1 A (maximum) becomes available on the EgV terminals of the connector to control an external gas valve. Additional external interlocks (by others) may be required in a multi boiler installation.
BlueEfficiency CLEANER / GREENER / SMARTER BlueEfficiency BlueEfficiency TreadLightly BlueEfficiency TreadLightly CLEANER / GREENER / SMARTER CLEANER / GREENER / SMARTER CLEANER / GREENER / SMARTER ON THE PLANET ON THE PLANET Remeha Commercial Innovation House 3 Oaklands Business Centre Oaklands Park Wokingham RG41 2FD T: 0118 978 3434 boilers@remeha.co.uk www.remeha.co.