Service manual

36
Remeha Avanta 18v
LTALW7H000047b
R
The parameters can be changed from the stand-by status as
follows:
Press the [enter]-key and briefly the [reset]- key until codes
c and 0 appear alternately in the display.
Press the [+]-key until access code 12 is displayed.
Press the [enter]-key until p1 appears (codes p [ and
[ 1 are displayed alternately);
This parameter can now be changed as follows;
Press the [enter]-key; the set value for the maximum flow
temperature now appears e.g.; 75 (75°C).
Press the [+] or [-]-key to change this value, for example to
65 (65°C).
Press [enter]-key to confirm the value; codes p [ and [
1 are displayed alternately.
Press the [+]-key to change the next parameter, etc.
Press [reset]-key to return to the operating mode.
The boiler will automatically return to the normal operating
mode if no keys are pressed for 10 minutes.
LT.AL.W7H.000.047