Service manual

38
Remeha Avanta 18v
LTALW7H000052b
R
2.10.10 Restore factory settings
The factory settings can be restored in the service level as fol-
lows:
1. After parameter p31 has shown, press the [+]-key; d
f and xx appear alternately;
2. Press -key; xx appears;
3. Read boiler identification plate for value of d f ; press [+]
or [-] key to reach this value;
4. Press -key to confirm; d U and yy appear alter-
nately;
5. Read boiler identification plate for value of d U ; press [+]
or [-] key to reach this value;
6. Press -key to confirm; boiler restarts with original factory
settings.
2.11 Putting the boiler out of operation
The boiler must be switched off and allowed to cool down
before any maintenance or repairs are carried out. If the cen-
tral heating system is not going to be used for a long time
(during the holidays, for instance, or frost-free periods) it is
advisable to put the boiler out of operation.
2.11.1 Boiler with frost protection, during longer periods
of non-use
Set the room thermostat or other controls to a low tempera-
ture, e.g. 10°C,
Switch setting p4 to 1 (Eco mode), this will switch off
the heat retention function.
Now the boiler will only start working to protect itself against
freezing.
With external frost protection, the boiler can also prevent the
central heating system from freezing.
2.11.2 Boiler without frost protection, during longer
periods of non-use
Turn time clock off and allow system to cool down then iso-
late mains power supply at the fused spur unit
Isolate the gas supply at the boiler valve
Drain the boiler and central heating system if you will not be
using the home for a long period and there is a chance of
night frost.
LT.AL.W7H.000.052