IPL6000_IB_BOOK_UK_ONLY.
SKIN CHART & i-LIGHT SYSTEM DIAGRAM REFERENCE Read instructions manual before use. Do not use on the face. Do not use near water. Figure1 6 5 7 8 4 9 3 10 1 17 2 11 13 18 14 12 14 4 12 4 15 2 IPL6000_IB_BOOK_UK_ONLY.
GB ENGLISH Getting acquainted with i-Light What is i-Light? i-Light is a home-use device for the removal of body hair using Intense Pulsed Light (IPL) technology. This is the same technology used in professional hair removal salons and clinics. If used correctly it can provide long-lasting hair reduction. What is Intense Pulse Light (IPL) and how does the i-Light work? 17 14 i-Light works by directing an extremely short, intense pulse of light into the skin.
ENGLISH Fig 2 Fig3 Fig4 Anagen Phase Catagen Phase Telogen Phase Warnings and Safety Precautions IMPORTANT SAFETY CAUTIONS Before you start using i-Light: Be sure to read all Warnings and Safety Information. Before you begin, check to see if i-Light is suitable for you. Use the skin chart, provided on the box and the front of this manual, and the integrated skin sensor to determine if this device is right for you. Skin Type See skin colour chart on page 2.
GB ENGLISH When not to use/When to avoid using i-Light. • Do not use if you are pregnant or breast feeding. • Do not use if you were exposed to sun or artificial tanning within the past 4 weeks. • Do not use on dry or fragile skin caused by the use of chemical peels, glycolic peels, Alpha Hydroxy Acids (AHAs). • Do not flash more than once on the same area as this may cause burns. • Do not use on the same area of your skin more than once a week.
ENGLISH To reduce the risk of injury or death by electric shock: • The appliance must only be used by or under the supervision of a responsible adult. • Use and store the appliance out of reach of children. • Always unplug the unit from the electrical outlet immediately after using. • Do not use near water. • Do not place or store this appliance where it can fall or be pulled into a tub or sink. • Do not place or drop into water or other liquid.
GB ENGLISH 14 Nose Cone Release Buttons 15 Light Cartridge 16 Nose Cone 17 Power Cord 18 Lint Free Cloth Familiarise yourself with the features of your new I-Light device. Flash Window (fig. 1-12) The Flash Window is a filtered glass window with built-in UV protection that allows specific wavelengths of light to pass from the hand piece to your skin and hair follicles. WARNING: Always inspect the Flash Window before use to ensure there is no damage to the lens.
ENGLISH WARNING: ALWAYS ensure the unit is OFF and the power cord is disconnected before removing the nose cone. If the nose cone is removed while the unit is powered ON, all indicator lights on the base unit will flash and audible “beeps” will sound. Getting acquainted with i-Light Light Cartridge (fig. 1-15) Each light cartridge has a life of 1,500 flashes. When all flashes have been used, the cartridge must be replaced. Replacement model: SP-6000 SB Intensity Level Selection (fig.
GB ENGLISH Treat desired area(s) with the i-Light device Prepare your skin for treatment 1. Ensure the area to be treated is clean and free from oils, deodorants, perfume, make up, lotions and creams. Shave the hair from the area to be treated. 2. Never use wax, epilation, tweezers, or depilation products to remove the hair because they counteract the IPL process. Prepare the device for treatment 3. Unwrap the hand piece cord from the i-Light base and rest the hand piece in the base cradle.
ENGLISH Single Flash Mode 1. Place the i-Light hand piece against your skin so the Flash Window is flush with the skin surface (fig. 8). 2. Ensure the Skin Contact Sensor is fully engaged and the Bulb Status Indicator Display is illuminated. 3. Press the Flash Button to activate the device (fig. 9). 4. Move the hand piece to a new treatment area and repeat steps 1-3 (fig. 10). Treat desired area(s) with the i-Light device – Multi Flash Mode 1.
GB ENGLISH Post-treatment care After treatment, you may experience slight redness or a warm sensation on your skin. This is normal and will disappear quickly. To avoid irritation to your skin after a treatment, take the following precautions: • Avoid sun exposure for 24 hours after a treatment. Protect the skin with SPF 30 for 2 weeks after each treatment. • Do not prolong sun exposure such as sunbathing, using a tanning bed, or self tan for at least 2 weeks after the last treatment.
ENGLISH Do not use petroleum-based or flammable cleaning agents because of the risk of fire. Never use scouring pads, abrasive cleaning agents or aggressive liquids such as oil or acetone to clean the unit. Troubleshooting / storage / maintenance i-Light Device Maintenance CAUTION: Before performing maintenance on your i-Light device, ensure that the power switch is OFF and the power cord is disconnected from the base unit. Replacing the bulb 1.
GB ENGLISH Frequently Asked Questions I have switched the unit ON, but I cannot increase or decrease the light intensity. • Try resetting the unit by turning it off and waiting several seconds before turning it back on. The Bulb Status Indicator Light turns green but the unit does not flash when the button is pressed. • Make sure the Skin Contact Sensor is in full contact with the skin. • Try resetting the unit by turning it off and waiting several seconds before turning it back on.
ENGLISH Frequently Asked Questions (www.remington-ilight.com) Q. What is i-Light? What is Intense Pulse Light (IPL)? A. IPL works by directing an extremely short, intense pulse of filtered light into the skin. The light is absorbed by the coloured pigments in and surrounding the hair and disables the hair follicle temporarily, preventing hair regrowth. Q. Who can use i-Light? A. Both men and women can use i-Light to remove unwanted hair anywhere below the neck.
GB ENGLISH Q. What are the warnings against using i-Light? A. Certain conditions may limit your ability to use the unit. Please read the Warnings and Safety Precautions section in the User Manual in its entirety before using i-Light. Q. How often do I need to replace the bulb? A. The bulb needs to be replaced after 1500 flashes. The Bulb Status Indicator Light will illuminate green for the first 1350 flashes of the cartridge life. It will turn to a yellow light to designate that only 150 flashes remain.
ENGLISH Q. Can I use i-Light if I am pregnant or nursing? A. No. i-Light has not been tested on pregnant women, therefore we do not recommend using i-Light if you are pregnant or breast feeding. Hormonal changes could increase sensitivity and the risk of injury to the skin. The Fitzpatrick Skin-Type Chart Applicable Skin Tones, Skin tone chart – Fitzpatrick skin types 1 – 4 You can use this skin-type chart for self-assessment, by adding up the score for each of the questions you’ve answered.
GB ENGLISH Reaction To Sun Exposure: Score 0 1 2 3 4 What happens when you stay in the sun too long? Painful redness, blistering, peeling Blistering followed by peeling Burns sometimes followed by peeling Rare burns Never had burns To what degree do you turn brown? Hardly or not at all Light colour, tan Reasonable tan Tan very easily Turn dark brown quickly Do you turn brown within several hours after sun exposure? Never Seldom Sometimes Often Always How does your face react to the
GE BE FR ITA SC AU SW ENGLISH SP PO Skin Type Score - Fitzpatrick Skin Type 0-7 8-16 17-25 25-30 Over30 UN T I II III IV V-VI Do Not Use i-Light Spectrum M35 0H ČES T VARTA B ČESKÁ R IREL TYPE 1: Highly sensitive, always burns, never tans. Example: Red hair with freckles. TYPE 2: Very sun sensitive, burns easily, tans minimally. Example: Fair skinned, fair haired Caucasians. TYPE 3: Sun sensitive skin, sometimes burns, slowly tans to light brown. Example: Darker Caucasians.
Central Europe Thetaco Cyprus, RO GERMANY BENELUX FRANCE ITALY SCANDINAVIA Mo.-Fr. 9 a.m. – 5 p.m. Central European Time (free call) AUSTRIA E-Mail: service@remington-europe.com SWITZERLAND www.remington-europe.com 00800 / 821 700 821 PORTUGAL Tel. +34 902 10 45 17; 08.00 - 13.00; lunes - viernes (Posventa) Tel. +34 932 070 166 (Información al consumidor final) Tel. +351 299 942 915; renase@presat.net UNITED KINGDOM Tel.
Model No. IPL6000 11/UK/IPL6000 Version 12/11 Part No. T22-33176 REMINGTON® is a Registered Trade Mark of Spectrum Brands,Inc., or one of its subsidiaries. VARTA Consumer Batteries GmbH & Co. KGaA Alfred-Krupp-Str.9 73479 Ellwangen Germany www.remington-europe.com © 2011 SBI IPL6000_IB_BOOK_UK_ONLY.