Contents Safety notes 4 Environmental protection and recycling 4 Warranty 4 Transportation and packaging 5 Description of the equipment 5 Combinations 5 Operation 6-13 Shutdown 14 Care and maintenance 14-15 Troubleshooting and customer service 16-17 Installation instructions for qualified personnel 18 Installation 19 Condensation connection 20 Electrical connection 21 Electrical connection diagram 21 Electrical circuit diagram 22 Commissioning 23 Unit dimensions 23 Explod
REMKO ATY Safety notes Carefully read this manual before starting the unit for the first time. It contains useful tips and notes as well as hazard warnings to prevent injury or material damage . Nonobservance of this manual may endanger persons, the environment as well as the equipment itself and will void any claims for liability. ■ Store this manual and the refrigerant datasheet in the vicinity of the unit. ■ The unit should only be set up and installed by qualified personnel.
Transportation and packaging The equipment has been shipped in sturdy packaging. Immediately check the equipment on delivery and make a note of any damage or missing parts on the delivery note. Inform the forwarding agent and contractual partner. Warranty claims at a later date will not be accepted.
REMKO ATY Operation The indoor unit is easy to operate using an infrared remote control. This is supplied as standard. The indoor unit beeps to acknowledge the correct transmission of data. If it is not possible to program the indoor unit using the remote control, it can also be manually operated. Manual operation Display on indoor unit The indoor unit can also be started manually. Press the button on the right of the unit to activate automatic mode. The display is lit according to the settings.
Buttons on the remote control 1. Automatic mode In this mode the equipment is running in cooling mode. 2. Cooling mode In this mode the room air is cooled to the preset target temperature. 3. Heating mode Heating mode is not supported. 4. Circulation mode In this mode the room air is circulated. 5. Dehumidifying mode In this mode the room is mainly dehumidified, the set temperature is maintained. "FAN" Button Press this button to set the required fan speed.
REMKO ATY Button functions A symbol is shown on the display to indicate that the settings are being transferred. ON/OFF Button Press the ON / OFF button to activate or deactivate the unit. The programmed settings and parameters are shown on the display before the unit switches off. ON/OFF / Buttons ON/OFF The remote control has its own temperature display. Press the / buttons to change the display to . The button reduces the desired target temperature, the button increases it.
AUTOMATIC Mode This mode is not supported. COOLING Mode In cooling mode the room air is cooled to the preset target temperature. The desired room temperature is set in 1 °C steps using the / buttons. If the room temperature reaches 1 °C above the set target temperature, the indoor unit starts to cool the room air. If the actual temperature falls approx. 0.5 °C below the set room temperature, the controller switches the cooling off.
REMKO ATY DEHUMIDIFY Mode In dehumidifying mode, the room temperature can be set between 18 °C and 30 °C. The low refrigerant temperature causes the air temperature at the finned heat exchanger to fall below the dew point. Any excess humdity in the air condenses in the finned heat exchanger. As a result the room is dehumidified. The fan speed cannot be altered. MODE FAN Button Press this button to set the fan speed. One can choose between low, medium, high and automatic fan speed.
SLEEP Button (hidden) Press the buttons to activate a program which will raise the target temperature in cooling mode by 1 °C and 2 °C after 1 and 2 hours respectively. SLEEP SLEEP SLEEP Diagram of function 1 hr. 2 hrs. 6 hrs. Target temperature +2°C Operation Target temperature +1°C Stop Unit operational TIMER Button (covered) This button is used to program the switch-on and switch-off times.
REMKO ATY TIMER OFF programming TIMER Unit shut down TIMER ON/OFF programming SET Programmed time reached The controller switches the unit on and off at the programmed times. During operation, all the settings are shown on the display. Only the timer settings are visible when the unit is shut down. Unit On Unit Off Example: The controller switches on at 09:00. The unit remains operational until 16:30.
I FEEL Button (hidden) The unit measures the temperature inside the wall-mounted equipment. This may differ from the temperature near the remote control. Press this button to send the temperature measured at the remote control to the wall-mounted unit. The temperature is continually adjusted to the actual temperature of the remote control (approx. every 5 minutes) providing the function is switched on.
REMKO ATY Shutdown Care and maintenance Temporary hutdown Regular care and observance of some basic points will ensure trouble-free operation and a long service life. 1. Let the indoor unit run for 2 to 3 hours in circulation mode, or in cooling mode at maximum temperature, to extract any residual humidity from the unit. CAUTION Prior to performing any work, ensure the equipment is isolated from the voltage supply and secured to prevent accidental switch-on! 2.
5. Clean off any dirt using lukewarm water and mild cleaning agents. The dirty side should be face down(Fig. 5). 6. If water is used, let the filter dry out properly in air before replacing it in the unit. 7. Carefully insert the filter. Ensure it locates correctly. 8. Close the lower display cover in the opposite order to that described above. Yearly Check / Maintenance / Inspection Six-monthly Type of task Monthly 4. Clean the filter using a normal vacuum cleaner.
REMKO ATY Troubleshooting and customer service The equipment and components are manufactured using state-of-the-art production methods and tested several times to verify their correct function. If malfunctions should occur, please check the functions as detailed in the list below. In the case of equipment that includes an indoor unit and an outdoor component, observe the chapters on "Troubleshooting and customer service" in both manuals.
Error indicated by flashing code Display Cause Required action 88 flashes Power outage for 3 minutes Switch off and switch back on E1 flashes Communication error display controller Contact specialist dealer E2 flashes Circulation sensor on indoor unit faulty/tripped Contact specialist dealer E3 flashes Frost protection sensor on indoor unit faulty/tripped Contact specialist dealer E4 flashes Vaporiser fan motor speed too low/faulty Contact specialist dealer E5 flashes No cooling/heating o
REMKO ATY Installation instructions for qualified personnel Important points prior to installation When installing a complete system, take into account the manuals for the indoor unit and outdoor component. ■ ■ ■ ■ ■ 18 ■ Transport the unit in its original packaging as close as possible to the installation location.This avoids transportation damage. Check that the packaged contents are complete and inspect the unit for any visible signs of transportation damage.
Installation NOTE 6 Open the display cover Installation should only be performed by authorised specialists. Connecting the refrigerant pipes The connections to the refrigerant pipes are made at the rear of the unit (responsibility of customer). Installing the unit The indoor unit is installed by taking into account the position of the air outlet. This can be at the top or bottom as well as at the sides.
REMKO ATY Condensation connection If the temperature falls below the dew point, condensation will form on the vaporiser of the indoor unit during cooling. 10 Condensation connection Condensation connection for indoor unit The collection tray below the vaporiser should be connected to the drain. ■ The condensation pipe should have a fall of min. 2 %. This is the responsibility of the customer.(Fig 10). If necessary, fit vapour diffusion tight insulation.
Electrical connection A protected mains supply and control cable should be connected to the outdoor component and indoor unit respectively. Connecting the indoor unit Make the connection as follows: 1. Dismantle the front of the unit as described in the chapter "Installing the unit". CAUTION All electrical installation work should be performed by specialist contractors. Isolate the voltage supply when connecting the electrical terminals. ■ Connecting the indoor unit 2.
REMKO ATY Electrical circuit diagram ATY 261 / ATY 351 CN 4 1 2 3 1 2 3 Vaporiser fan CN 1 1 2 3 4 5 1 2 3 4 5 Hubmotor Hubmotor Front 1 Front 2 CN 11 1 2 3 4 5 1 2 3 4 5 Swingmotor Swingmotor Swingmotor Lamelle 1 Lamelle 2 Lamelle 3 CN 10 1 2 3 4 5 1 2 3 4 5 2 3 3 4 4 4 1 1 2 2 Sicherung 250V 3A CN 9 2 4 N3 N2 N1 Sensor Frostschutz Ionen-Generator Ry3 Ry3 Ry2 Ry1 3 1 2 3 4 5 1 2 3 4 5 1 3 CN 7 1 3 3 2 CN 8 4 4 2 2 1 1 2 3 4 5 1 2 3 4 5 3 3 2 CN 3 CN 6 2
Commissioning NOTE Commissioning should only be performed and documented by specially trained personnel. When starting up the complete system, observe the instructions given in the manuals for the indoor unit and outdoor component. Functional test for cooling mode 1. Switch on the supply voltage on. 2. Use the remote control to switch on the unit and select the cooling mode, maximum fan speed and lowest target temperature. 3.
REMKO ATY Exploded view ATY 261 / ATY 351 1 3 17 15 13 7 4 5 11 2 10 5 12 7 14 14 6 7 8 We reserve the right to modify the dimensions and constructional design as part of the ongoing technical development process.
Spare parts list No.
REMKO ATY Technical data Series ATY 261 Operating mode ATY 351 Wall-mounted air-conditioning unit for cooling applications Nominal cooling output 1) kW Energy efficiency class, cooling 1) Energy efficiency ratio EER 1) Operating range (room volume), approx. m³ Working range, indoor unit °C Adjustment range, cooling °C 2.67 3.56 B C 3.06 2.87 80 110 +16 to +32 +18 to +30 Refrigerant +18 to +30 R 410A Max.
Notes
REMKO ACROSS EUROPE … and in your area! Profit from our experience and advice Consultancy Intensive training means our consultants are always up-to-date with the latest developments. This has given us the reputation of being more than just a good and reliable supplier: REMKO, a partner who helps solve problems. Sales REMKO not only has a wellestablished sales network at home and abroad, it also employs highly trained sales specialists.