User`s manual

SAVING PROGRAMS SECTION 3
Page 3-3 RPC-320
29C040 512K [1-3], [2-4]
To change the EPRO M in U6, remove the IC and
replace it with the new one. When installing a 29C256,
pin 1 on the IC goes into socket pin 3. The top two
rows of pins are empty.
ALTERNATE EPROMS
Flash EPROMs are more expensive than UV er asable or
OTPs as of this writing. Large volume OEM' s may
wish to use lower cost EPRO Ms.
Program development must use flash EPROM s. When a
program is finished, the flash EP ROM is used as a
master. Use an external program to duplicate progr ams.
Jumper W2 is normally configured for flash EPROM
(W2[3-5] and W2[4-6]). For non-flash EPRO Ms, W2 is
configured for [1-3] and [2-4]. Large volume OEM's
should contact Remote Processing regarding pre-
configuring W2 and W3 for your application.
COMMANDS
The following is a list of RPBASIC-52 commands used
for saving, loading, and executing programs and data.
These commands and functions are explained in the
Software Supplement in this manual.
Command Function
BLOAD Transfers binary data from
EPROM to RAM
BSAVE Transfers binary data from RAM
to flash EPROM
EXECUTE Loads, clears memory, then runs
a program from within a program
LOAD n Loads a program from EPROM
SAVE n Saves a program to flash EPROM