IR Learning Mapping Table (Parameter number 25)
- Make sure your original remote is switched to power off.
- Press the key on original remote before learning mode timeout.
- Keep away from incandescent light and direct sunlight during learning.
- Make sure IR Transmitter of your original remote alight with learning diode of ZXT-
120, you may also slight adjust closer or further away the distance of two devices.
Some of remotes the IR transmitter in hidden behind lens and may not installed
center of remote.
- Make sure the power is good on both devices, especially the original remote. Use
fresh batteries.
When you encounter problem, check followings:
Parameter Value
(Storage Location)
Storage in Celsius unit
Storage in Fahrenheit unit
Thermostat command & IR setting
0 OFF OFF
1 ON (resume) ON (resume)
2
o
19 C cool
o
67 F cool
3
o
20 C cool
o
68 or 69 F cool
4
o
21 C cool
o
70 or 71 F cool
5
o
22 C cool
o
72 or 73 F cool
6
o
23 C cool
o
74 or 75 F cool
7
o
24 C cool
o
76 F cool
8
o
25 C cool
o
77 or 78 F cool
9
o
26 C cool
o
79 or 80 F cool
10
o
27 C cool
o
81 or 82 F cool
11
o
28 C cool
o
83 or 84 F cool