User's Manual

Table Of Contents
Z-Wave Configuration Parameters
Parameter No. Definitions Parameter Value
25 (0x19)
Indicate a location for IR code
learning and start learning
0-22 (0x00 0x16)
26 (0x1A)
Learning status register
Note:
The status value 0x01 and
0x04 will be reset to 0 when
the ZXT-120 receive a get
command to this parameter
0(0x00): Idle - this IR channel
is idle (default)
1(0x01): OK - the latest
learning process
successful and
completed
2(0x02): Learning - the ZXT-
120 is busy
processing previous
learning request
4(0x04): Failed - the latest
learning request failed
27 (0x1B)
IR code number for built-in
code library
Refer "Code list" for details
28 (0x1C)
External IR Emitter power
level
0(0x00): normal power mode
255(0xFF):high power mode
(default)
32 (0x20)
Surround IR control
- to avoid the IR interference
by disabling the
surrounding IR emitter if 2
air-conditioners in a room
are used
- extend the battery life by
disabling the Surround IR
Emitters
0(0x00): disable Surround IR
Emitters
255(0xFF):enable Surround IR
Emitters (default)
15