User's Manual

15
Calibrate
temperature
reading
37 (0x25)
Temperature oset value.
0x00 = 0°C (Default)
0x01 = 1°C
0x02 = 2°C
0x03 = 3°C
0x04 = 4°C
0x05 = 5°C
0xFF = -1°C
0xFE = -2°C
0xFD = -3°C
0xFC = -4°C
0xFB = -5°C
1
Set Auto
Report
Condition
Trigger
By Room
Temperature
change
30 (0x1E)
0x00 = Disable AUTO report function
(Default)
(for saving battery life)
Auto report if room temperature is
dierent from last report.
0x01 = 1°F (0.5°C)
0x02 = 2°F (1°C)
0x03 = 3°F (1.5°C)
0x04 = 4°F (2°C)
0x05 = 5°F (2.5°C)
0x06 = 6°F (3°C)
0x07 = 7°F (3.5°C)
0x08 = 8°F (4°C)
1
Set Auto
Report
Condition
By
Time Interval
34 (0x22)
0x00 = Disable AUTO report function
(Default)
Auto report by the following time
interval.
0x01 = 1 Hr
0x02 = 2 Hrs
0x03 = 3 Hrs
0x04 = 4 Hrs
0x05 = 5 Hrs
0x06 = 6 Hrs
0x07 = 7 Hrs
0x08 = 8 Hrs
1