User's Manual

6
Notes:
1. It is recommended to perform the Remove (Exclude) procedure before per-
forming an Add (Include) procedure.
2. Red Indicator ashes TWICE then stay off to represent the Add / Remove pro-
cess failed, please repeat the above step again.
3. If the Add (Include) process fails, try Remove (Exclude) and /or resetting the
AC Master to Factory Default and repeat the above step.
Step 3 Setup Automatic Status Report Association to Gateway
Step 4 Setup Air Conditioner IR code
The UI of set up the IR code varies from dierent gateways. If gate-
ways have dedicated UI for the IR code setup please refer to the
gateway UI and ignore the below steps.
If your gateway does not have dedicated UI for ZXT-600 IR code
setup, but support Z-Wave thermostat Command Class and Con-
guration Command Class. You may refer to below steps to setup
the IR code using the conguration options in your gateway
ZXT-600 supports 1 association group
Association Group #1
Association Group #1 (max. 1 node) is default to associate with the
primary controller (Gateway/Hub/Controller) for AC Master Status
change report, refer to below for report details:
Current Room Temperature (report in precision of 0.5°C or 1°F) (It
will be according to Conguration Parameter 39 setting to decide
the trigger level)
Current Battery Level (Only apply in Low Battery Warning hap-
pened)
Device Reset Locally Notication (Only report when the AC Master
has been triggered the RESET TO DEFAULT)