Users Manual

Table Of Contents
R01UH0823EJ0110 Rev.1.10 Page 1084 of 1852
Nov 30, 2020
RX23W Group 33. Serial Communications Interface (SCIg, SCIh)
33.10 Extended Serial Mode Control Section: Description of Operation
33.10.1 Serial Transfer Protocol
The extended serial mode control section of the SCI12 can realize the serial transfer protocol composed of Start Frames
and Information Frames that is shown in
Figure 33.60.
A Start Frame is composed of a Break Field, Control Field 0, and Control Field 1. An Information Frame is composed of
a number of Data Fields, a CRC16 Upper Field, and a CRC16 Lower Field.
Figure 33.60 Protocol for Serial Transfer by the Extended Serial Mode Control Section
Start Frame
Information Frame
Break Field
Break Field low width
Break Field
high width
Inter Field Space Inter Field Space
Control Field 0 Control Field 1 Data Field
Data Field Data Field Data Field CRC16 Upper Field CRC16 Lower Field
Information Frame
Inter Field Space Inter Field Space Inter Field Space Inter Field Space
8 bits
8 bits
8 bits 8 bits 8 bits 8 bits
8 bits 8 bits