REJ10J1937-0100 SH72546RFCC SH72544R SH72543R User-System Interface Converter Board R0E572546CBF10 Converter Board User’s Manual Renesas Microcomputer Development Environment System SuperH™ Family / SH72546RFCC, SH72544R, and SH72543R Rev.1.00 Revision Date: Nov.
Rev. 1.00 Nov.
Notes regarding these materials 1. This document is provided for reference purposes only so that Renesas customers may select the appropriate Renesas products for their use. Renesas neither makes warranties or representations with respect to the accuracy or completeness of the information contained in this document nor grants any license to any intellectual property rights or any other rights of Renesas or any third party with respect to the information in this document. 2.
Rev. 1.00 Nov.
IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this emulator product. • KEEP the user's manual handy for future reference. Do not attempt to use the emulator product until you fully understand its mechanism. Emulator Product: Throughout this document, the term "emulator product" shall be defined as the following products produced only by Renesas Technology Corp. and Renesas Solutions Corp. excluding all subsidiary products.
Target User of the Emulator Product: This emulator product should only be used by those who have carefully read and thoroughly understood the information and restrictions contained in the user's manual. Do not attempt to use the emulator product until you fully understand its mechanism. It is highly recommended that first-time users be instructed by users that are well versed in the operation of the emulator product.
LIMITED WARRANTY Renesas warrants its emulator products to be manufactured in accordance with published specifications and free from defects in material and/or workmanship. Renesas, at its option, will replace any emulator products returned intact to the factory, transportation charges prepaid, which Renesas, upon inspection, shall determine to be defective in material and/or workmanship. The foregoing shall constitute the sole remedy for any breach of Renesas’ warranty.
State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may have other rights which may vary from state to state.
SAFETY PAGE READ FIRST • READ this user's manual before using this emulator product. • KEEP the user's manual handy for future reference. Do not attempt to use the emulator product until you fully understand its mechanism. DEFINITION OF SIGNAL WORDS Either in the user's manual or on the product, several icons are used to insure proper handling of this product and also to prevent injuries to you or other persons, or damage to your properties. Their graphic images and meanings are given in this safety page.
means WARNING or CAUTION. Example: CAUTION AGAINST AN ELECTRIC SHOCK means PROHIBITION. Example: DISASSEMBLY PROHIBITED means A FORCIBLE ACTION. Example: UNPLUG THE POWER CABLE FROM THE RECEPTACLE. Rev. 1.00 Nov.
WARNING Warnings for AC Power Supply: • If the attached AC power cable does not fit the receptacle, do not alter the AC power cable and do not plug it forcibly. Failure to comply may cause electric shock and/or fire. • Use an AC power cable which complies with the safety standard of the country. • Do not touch the plug of the AC power cable when your hands are wet. This may cause electric shock. • This product is connected signal ground with frame ground.
WARNING • If you smell a strange odor, hear an unusual sound, or see smoke coming from this product, then disconnect power immediately by unplugging the AC power cable from the outlet. Do not use this as it is because of the danger of electric shock and/or fire. In this case, contact your local distributor. • When installing or connecting this product with other equipment, shut down AC power or disconnect the AC power cord from the equipment to prevent personal injury or damage to the equipment.
CAUTION Cautions for AC Adapter: • Use only the AC adapter included in this product package. • The included AC adapter is for this emulator. Do not use it for other product. • The DC plug on the included AC adapter has the below polarity. • The included AC adapter has no power supply switch. The AC adapter is always active while connecting the AC power cable. Check if the power is supplied by the LED of AC adapter. Cautions to Be Taken for This Product: • Use caution when handling this product.
WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance. 2. Always switch OFF the E200F emulator and user system before connecting or disconnecting any CABLES or PARTS. 3.
Preface The R0E572546CBF10 is a user-system interface converter board that connects a user system for the SH72546RFCC, SH72544R, and SH72543R PRBG0272FA-A package (former package: BP-272) to the SH72546RFCC, SH72544R, SH72543R, SH72531, and SH72531FCC E200F emulator (R0E0200F1EMU00 or R0E572546VKK00).
Contents Preface .....................................................................................................................1 Section 1 Configuration.........................................................................................1 Section 2 Environmental Conditions..................................................................... 3 Section 3 Connection Procedures ..........................................................................5 3.1 3.2 3.
Section 1 Configuration Section 1 Configuration Figure 1 and table 1 show the external appearance and components, respectively, of the user-system interface converter board. Please make sure you have all of these components when you unpack the product.
Section 1 Configuration CAUTION 1. Use a BSSOCKET272Z2021RE21N socket (manufactured by Tokyo Eletech Corporation), and a CSPLUG/W272Z2021RE01 (manufactured by Tokyo Eletech Corporation) for the PRBG0272FA-A package IC socket, and IC socket plug, respectively, on the user system. 2. To connect the emulator with user-system interface converter board, the common user-system interface adaptor cable (R0E200F1CKL00) must be obtained separately. 3.
Section 2 Environmental Conditions Section 2 Environmental Conditions Maintain the conditions in table 2 when using the emulator. Table 2 Environmental Conditions Item Specifications Temperature Operating: +10 to +35°C Storage: -10 to +35°C Humidity Operating: 35 to 80% RH, no condensation Storage: 35 to 80% RH, no condensation Vibration Operating: 2.45 m/s max. 2 Storage: 4.9 m/s max. 2 Transportation: 14.7 m/s max. Ambient gases There must be no corrosive gases present. 2 Rev. 1.00 Nov.
Section 2 Environmental Conditions Rev. 1.00 Nov.
Section 3 Connection Procedures Section 3 Connection Procedures 3.1 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY.
Section 3 Connection Procedures 3.1.1 Installing the IC Socket Solder the IC socket (BSSOCKET272Z2021RE21N) to the user system. CAUTION 1. Gently apply solder paste to the BGA pads of the user system. Be careful to keep the thickness of the solder within 100 to 150 μm. Too much solder will cause short-circuiting of the pins. 2. A strip of protective (polyimide) tape is stuck to the surface of the IC socket which is to be connected to the IC socket plug.
Section 3 Connection Procedures Connect the common user-system interface cable (cable unit) to CONNECTOR1 of the common user-system interface adaptor cable (board unit) as shown below. Then connect the common user system interface adaptor cable (cable unit) to CONNECTOR2. Connect the common user-system interface adaptor cable (cable unit) to CONNECTOR3.
Section 3 Connection Procedures __ _ __ __ _ Removing the common user-system interface adaptor cable (cable unit). When removing the common-user system interface adaptor cable (cable unit) from a converter board or a adaptor board, keep the board in place, hold both sides of the connector at the head of the cable, and apply vertical force to pull the cable away. If the join is stiff so that the cable is dificult to remove, pull the cable head up from the right or left side.
Section 3 Connection Procedures 3.1.3 Connecting Common User-System Interface Adaptor Cable (Board Unit) to EV-Chip Unit WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1.Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part.
Section 3 Connection Procedures Expansion AUD trace unit Ev-chip unit Connector number Ev-chip unit connector side connector number Common user-system interface adaptor cable (board unit) side connector number User I/F Connector 1 (CN3) UCN1 User I/F Connector 2 (CN4) UCN2 Common user-system interface adaptor cable (board unit) Figure 4 Connecting Common User-System Interface Adaptor Cable (Board Unit) to EV-Chip Unit Rev. 1.00 Nov.
Section 3 Connection Procedures 3.1.4 Installing to the IC Socket CAUTION 1. Check the location of pin 1 before insertion. 2. Do not fail to insert the guide pin of the IC socket plug in the user system side. Use the provided IC socket plug to fasten the user-system interface converter board to the IC socket for a PRBG0272FA-A package on the user system. Apply vertical force to fasten the parts together.
Section 3 Connection Procedures 3.2 Dimensions 3.2.1 Recommended Dimensions for User System Mount Pad (Footprint) Figure 6 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for a PRBG0272FA-A package (BSSOCKET272Z2021RE21N: manufactured by Tokyo Eletech Corporation). 1.0 x 19 = 19.0 1.0 φ0.5 Dimension and tolerance Tolerance Dimension ±0.05 Up to 1.2 ±0.10 1.3 to 2.0 ±0.15 2.1 to 5.0 ±0.20 5.1 to 10.0 10.1 or above ±0.
Section 3 Connection Procedures 3.2.2 External Dimensions The external dimensions of the expansion AUD trace unit, emulation memory unit, EV-chip unit, common user-system interface adaptor cable (board unit), common user-system interface adaptor cable (cable unit), and user-system interface converter board are shown in figure 7. 125.0 90.0 90.0 125.0 Expansion AUD trace unit Emulation memory unit 60.0 90.0 90.0 110.0 20.0 49.0 5.81 125.
Section 3 Connection Procedures 3.2.3 Dimensions of User-System Interface Converter Board when Connected 21.10 16.45 35.0 5.95 19.5 14.5 Dimensions of the user-system interface converter board when it is connected to the user system are shown in figure 8. Top view 21.1 43.5 Bottom view Dimension and tolerance Dimension Tolerance to 1.2 ±0.05 1.3 to 2.0 ±0.10 2.1 to 5.0 ±0.15 5.1 to 10.0 ±0.20 ±0.30 10.
Section 3 Connection Procedures 3.3 Verifying Operation 1. Turn on the emulator according to the procedures described in the SH-2A, SH-2 E200F Emulator User's Manual, Supplementary information on Using the SH72546RFCC, SH72544R, SH72543R, SH72531, and SH72531FCC (R0E0200F1EMU00E or R0E572546EMU00E). 2. The emulator connected to this user-system interface converter board supports two kinds of clock sources as the MPU clock.
Section 3 Connection Procedures Rev. 1.00 Nov.
Section 4 Notice Section 4 Notice 1. Before connecting any parts or cables, make sure that pin 1 on the both sides are correctly aligned. 2. Do not apply excessive force to the user-system interface converter board while it is connected to the user system. 3. The dimensions of the recommended mount pad for the IC socket for this user-system interface converter board are different from those of the MPU. 4.
Section 4 Notice Rev. 1.00 Nov.
SH72546RFCC SH72544R SH72543R User-System Interface Converter Board User's Manual Publication Date: Rev.1.00, November 18, 2008 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Customer Support Department Global Strategic Communication Div. Renesas Solutions Corp. © 2008. Renesas Technology Corp. All rights reserved. Printed in Japan.
Sales Strategic Planning Div. Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japan RENESAS SALES OFFICES http://www.renesas.com Refer to "http://www.renesas.com/en/network" for the latest and detailed information. Renesas Technology America, Inc. 450 Holger Way, San Jose, CA 95134-1368, U.S.A Tel: <1> (408) 382-7500, Fax: <1> (408) 382-7501 Renesas Technology Europe Limited Dukes Meadow, Millboard Road, Bourne End, Buckinghamshire, SL8 5FH, U.K.
SH72546RFCC SH72544R SH72543R User-System Interface Converter Board User’s Manual