Converter Board User's Manual

( 3 / 4 )
Figure 3 Connecting procedure
5. Connection Procedure (See Figure 3)
The procedure for connecting the M3T-100LCC-QSD is
shown below.
(1) Mount the TQPACK100SD on the target system.
(2) Attach the TQSOCKET100SDG to the TQPACK100SD.
(3) Attach the M3T-100LCC-QSD to the TQSOCKET100SDG.
M3T-100LCC-QSD
TQSOCKET100SDG
(3)
(2)
(1)
TQPACK100SD
100-pin 0.5-mm-pitch
(100P6Q-A or 100P6D-A)
foot pattern
: No. 1 pin position
Be sure to align the pins.
6. External Dimensions and a Sample Foot Pattern
Unit: mm
Figure 4 External dimensions of the M3T-100LCC-QSD and its sample foot pattern