Section 20 LPC Interface (LPC)
Rev. 2.00 Sep. 28, 2009 Page 670 of 994
REJ09B0452-0200
Figure 20.5 shows the timing of the LPCPD and LRESET signals.
LPCPD
LRESET
LAD3 to LAD0
LFRAME
LCLK
At least 30 µs
At least 100 µs
At least 60 µs
Figure 20.5 Power-Down State Termination Timing