Datasheet

Section 10 16-Bit Timer Pulse Unit (TPU)
Rev. 3.00 Sep. 28, 2009 Page 270 of 910
REJ09B0350-0300
(b) Examples of waveform output operation
Figure 10.10 shows an example of 0 output/1 output. In this example TCNT has been designated
as a free-running counter, and settings have been made so that 1 is output by compare match A,
and 0 is output by compare match B. When the set level and the pin level coincide, the pin level
does not change.
TCNT value
H'FFFF
H'0000
TIOCA
TIOCB
Time
TGRA
TGRB
No change No change
No change No change
1 output
0 output
Figure 10.10 Example of 0 Output/1 Output Operation
Figure 10.11 shows an example of toggle output.
In this example TCNT has been designated as a periodic counter (with counter clearing performed
by compare match B), and settings have been made so that output is toggled by both compare
match A and compare match B.
TCNT value
H'FFFF
H'0000
TIOCB
TIOCA
Time
TGRB
TGRA
Toggle output
Toggle output
Counter cleared by TGRB compare match
Figure 10.11 Example of Toggle Output Operation