Section 23 Clock Pulse Generator
Rev. 3.00 Sep. 28, 2009 Page 761 of 910
REJ09B0350-0300
Table 23.2 Crystal Resonator Parameters
Frequency (MHz) 8 10 12 16 20
R
S
(max) (Ω) 80 70 60 50 40
C
0
(max) (pF) 7 7 7 7 7
23.1.2 External Clock Input Method
Figure 23.4 shows a typical method of inputting an external clock signal. To leave the XTAL pin
open, incidental capacitance should be 10 pF or less. To input an inverted clock to the XTAL pin,
the external clock should be set to high in standby mode or watch mode. External clock input
conditions are shown in table 23.3. The frequency of the external clock should be the same as that
of the system clock (φ).
EXTAL
XTAL
EXTAL
XTAL
External clock input
Open
(a) Example of external clock input when XTAL pin is left open
External clock input
(b) Example of external clock input when an inverted clock is input to XTAL pin
Figure 23.4 Example of External Clock Input