Datasheet
Section 14 IEBus™ Controller (IEB) [H8S/2258 Group] 
Rev. 6.00 Mar. 18, 2010 Page 513 of 982 
REJ09B0054-0600 
Bit Bit Name 
Initial 
Value 
R/W Description 
5  SRQ  0  R  Slave Transmission Request 
Indicates whether or not the unit is in transmit request 
status as a slave unit. 
1: The unit is in transmit request status as a slave unit 
[Setting condition] 
When the CMX flag is cleared to 0 after the slave transmit 
request command is issued. 
0: The unit is not in transmit request status as a slave unit 
[Clearing condition] 
When a slave transmission has been completed. 
4  SRE  0  R  Slave Receive Status 
Indicates the execution status in slave/broadcast reception. 
1: Slave/broadcast reception is being executed 
[Setting condition] 
When the slave/broadcast reception is started while the RE 
bit in IECTR is set to 1. 
0: Slave/broadcast reception is not being executed 
[Clearing condition] 
When the slave/broadcast reception has been completed. 
3  LCK  0  R  Lock Status Indication 
Set to 1 when a unit is locked by a lock request from the 
master unit. IELA1 and IELA2 values are valid only when 
this flag is set to 1. 
1: A unit is locked 
[Setting condition] 
When data for the number of bytes specified by the 
message length is not received after the control bits that 
make the unit locked are received from the master unit. 
(The LCK flag is set to 1 only when the message length 
exceeds the maximum number of transfer bytes in one 
frame. This flag is not set by completion of other errors.) 
0: A unit is unlocked 
[Clearing condition] 
When an unlock condition is satisfied or when an unlock 
command is issued. 










