Datasheet
Section 15 Serial Communication Interface (SCI) 
Rev. 6.00 Mar. 18, 2010 Page 593 of 982 
REJ09B0054-0600 
Table 15.11 shows the states of the SSR status flags and receive data handling when a receive 
error is detected. If a receive error is detected, the RDRF flag retains its state before receiving 
data. Reception cannot be resumed while a receive error flag is set to 1. Accordingly, clear the 
ORER, FER, PER, and RDRF bits to 0 before resuming reception. Figure 15.12 shows a sample 
flow chart for serial data reception. 
Table 15.11  SSR Status Flags and Receive Data Handling 
SSR Status Flag 
RDRF
*
  ORER  FER  PER  Receive Data  Receive Error Type 
1 1 0 0 Lost  Overrun error 
0 0 1 0 Transferred to RDR Framing error 
0 0 0 1 Transferred to RDR Parity error 
1 1 1 0 Lost  Overrun error + framing error 
1 1 0 1 Lost  Overrun error + parity error 
0  0  1  1  Transferred to RDR  Framing error + parity error 
1 1 1 1 Lost  Overrun error + framing error + 
parity error 
Note:  *  The RDRF flag retains the state it had before data reception. 










