Datasheet
Section 9 16-Bit Timer Pulse Unit (TPU) 
Rev.7.00 Feb. 14, 2007  page 334 of 1108 
REJ09B0089-0700 
Bit 6—Reserved: This bit cannot be modified and is always read as 1. 
Bit 5—Underflow Flag (TCFU): Status flag that indicates that TCNT underflow has occurred 
when channels 1, 2, 4, and 5 are set to phase counting mode. 
In channels 0 and 3, bit 5 is reserved. It is always read as 0 and cannot be modified. 
Bit 5 
TCFU 
Description 
0  [Clearing condition]   (Initial value) 
When 0 is written to TCFU after reading TCFU = 1 
1 [Setting condition] 
When the TCNT value underflows (changes from H'0000 to H'FFFF) 
Bit 4—Overflow Flag (TCFV): Status flag that indicates that TCNT overflow has occurred. 
Bit 4 
TCFV 
Description 
0  [Clearing condition]   (Initial value) 
When 0 is written to TCFV after reading TCFV = 1 
1 [Setting condition] 
When the TCNT value overflows (changes from H'FFFF to H'0000 ) 
Bit 3—Input Capture/Output Compare Flag D (TGFD): Status flag that indicates the 
occurrence of TGRD input capture or compare match in channels 0 and 3. 
In channels 1, 2, 4, and 5, bit 3 is reserved. It is always read as 0 and cannot be modified. 
Bit 3 
TGFD 
Description 
0  [Clearing conditions]   (Initial value) 
•  When DTC is activated by TGID interrupt while DISEL bit of MRB in DTC is 0 
•  When 0 is written to TGFD after reading TGFD = 1 
1 [Setting conditions] 
•  When TCNT = TGRD while TGRD is functioning as output compare register 
•  When TCNT value is transferred to TGRD by input capture signal while TGRD is 
functioning as input capture register 