Section 10 16-Bit Timer Pulse Unit (TPU) 
Rev.6.00 Mar. 18, 2009 Page 459 of 980 
REJ09B0050-0600 
10.4.6 Phase Counting Mode 
In phase counting mode, the phase difference between two external clock inputs is detected and 
TCNT is incremented/decremented accordingly. This mode can be set for channels 1, 2, 4, and 5. 
When phase counting mode is set, an external clock is selected as the counter input clock and 
TCNT operates as an up/down-counter regardless of the setting of bits TPSC2 to TPSC0 and bits 
CKEG1 and CKEG0 in TCR. However, the functions of bits CCLR1 and CCLR0 in TCR, and of 
TIOR, TIER, and TGR are valid, and input capture/compare match and interrupt functions can be 
used. 
This can be used for two-phase encoder pulse input. 
When overflow occurs while TCNT is counting up, the TCFV flag in TSR is set; when underflow 
occurs while TCNT is counting down, the TCFU flag is set. 
The TCFD bit in TSR is the count direction flag. Reading the TCFD flag provides an indication of 
whether TCNT is counting up or down. 
Table 10.31 shows the correspondence between external clock pins and channels. 
Table 10.31  Clock Input Pins in Phase Counting Mode 
  External Clock Pins 
Channels A-Phase B-Phase 
When channel 1 or 5 is set to phase counting mode  TCLKA  TCLKB 
When channel 2 or 4 is set to phase counting mode  TCLKC  TCLKD 