Datasheet
Section 15 I
2
C Bus Interface2 (IIC2) (Option) 
Rev.6.00 Mar. 18, 2009 Page 646 of 980 
REJ09B0050-0600 
TDRE
[6] Issue stop condition. Clear TEND.
[7] Set slave receive mode
TEND
ICDRT
ICDRS
19 23456789
AA/
SCL
(master output)
SDA
(master output)
SDA
(slave output)
Bit 7 Bit 6
Data n
Data n
Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
[5] Write data to ICDRT. Clear TDRE.
User
processing
Figure 15.6 Master Transmit Mode Operation Timing 2 
15.4.3 Master Receive Operation 
In master receive mode, the master device outputs the receive clock, receives data from the slave 
device, and returns an acknowledge signal. For master receive mode operation timing, refer to 
figures 15.7 and 15.8. The reception procedure and operations in master receive mode are shown 
below. 
1.  Clear the TEND bit in ICSR to 0, then clear the TRS bit in ICCRA to 0 to switch from master 
transmit mode to master receive mode. Then, clear the TDRE bit to 0. 
2.  When ICDRR is read (dummy data read), reception is started, and the receive clock is output, 
and data received, in synchronization with the internal clock. The master device outputs the 
level specified by ACKBT in ICIER to SDA, at the 9th receive clock pulse. 
3.  After the reception of first frame data is completed, the RDRF bit in ICST is set to 1 at the rise 
of 9th receive clock pulse. At this time, the received data is read by reading ICDRR. 
4.  The continuous reception is performed by reading ICDRR and clearing RDRF to 0 every time 
RDRF is set. If 8th receive clock pulse falls after reading ICDRR by the other processing while 
RDRF is 1, SCL is fixed low until ICDRR is read. 
5.  If next frame is the last receive data, set the RCVD bit in ICCR1 to 1 before reading ICDRR. 
This enables the issuance of the stop condition after the next reception. 
6.  When the RDRF bit is set to 1 at rise of the 9th receive clock pulse, read ICDRR. Then, clear 
RCVD. 