Datasheet
Section 26 Electrical Characteristics
Rev.7.00 Mar. 18, 2009 page 1055 of 1136
REJ09B0109-0700
(2) Control Signal Timing
Table 26.32 Control Signal Timing
Conditions: V
CC
= 3.0 V to 3.6 V, AV
CC
= 3.0 V to 3.6 V, V
ref
= 3.0 V to AV
CC
, V
SS
= AV
SS
=
0 V, φ = 8 MHz to 34 MHz, T
a
= −20°C to +75°C (regular specifications),
T
a
= −40°C to +85°C (wide-range specifications)
Item Symbol Min. Max. Unit Test Conditions
RES setup time t
RESS
200 ⎯ ns Figure 26.5
RES pulse width t
RESW
20 ⎯ t
cyc
NMI setup time t
NMIS
150 ⎯ ns Figure 26.6
NMI hold time t
NMIH
10 ⎯
NMI pulse width (in recovery from
software standby mode)
t
NMIW
200 ⎯
IRQ setup time t
IRQS
150 ⎯ ns
IRQ hold time t
IRQH
10 ⎯
IRQ pulse width (in recovery from
software standby mode)
t
IRQW
200 ⎯