11.2.10 Module Stop Control Register A (MSTPCRA)
Bit : 7 6 5 4 3 2 1 0
MSTPA7 MSTPA6 MSTPA5 MSTPA4 MSTPA3 MSTPA2 MSTPA1 MSTPA0
Initial value : 0 0 1 1 1 1 1 1
R/W : R/W R/W R/W R/W R/W R/W R/W R/W
MSTPCRA is an 8-bit readable/writable register that performs module stop mode control.
When the MSTPA5 bit in MSTPCRA is set to 1, TPU operation stops at the end of the bus cycle
and a transition is made to module stop mode. Registers cannot be read or written to in module
stop mode. For details, see section 24.5, Module Stop Mode.
MSTPCRA is initialized to H'3F by a power-on reset and in hardware standby mode. It is not
initialized by a manual reset and in software standby mode.
Bit 5—Module Stop (MSTPA5): Specifies the TPU module stop mode.
Bit 5
MSTPA5 Description
0 TPU module stop mode cleared
1 TPU module stop mode set (Initial value)