Datasheet
Section 11 16-Bit Timer Pulse Unit (TPU)
Page 622 of 1434 R01UH0166EJ0600 Rev. 6.00
Mar 02, 2011
H8S/2633 Group, H8S/2633 F-ZTAT
TM
,
H8S/2633R F-ZTAT
TM
, H8S/2695
11.6.2 Interrupt Signal Timing
TGF Flag Setting Timing in Case of Compare Match: Figure 11.42 shows the timing for
setting of the TGF flag in TSR by compare match occurrence, and TGI interrupt request signal
timing.
TGR
TCNT
TCNT input
clock
φ
N
N N+1
Compare
match signal
TGF flag
TGI interrupt
Figure 11.42 TGI Interrupt Timing (Compare Match)