Datasheet

Section 16 Serial Communication Interface (SCI, IrDA)
(The H8S/2695 is not equipped with an IrDA function)
Page 730 of 1434 R01UH0166EJ0600 Rev. 6.00
Mar 02, 2011
H8S/2633 Group, H8S/2633 F-ZTAT
TM
,
H8S/2633R F-ZTAT
TM
, H8S/2695
Channel Name Abbreviation R/W Initial Value Address
*
1
3 Serial mode register 3 SMR3 R/W H'00 H'FDD0
Bit rate register 3 BRR3 R/W H'FF H'FDD1
Serial control register 3 SCR3 R/W H'00 H'FDD2
Transmit data register 3 TDR3 R/W H'FF H'FDD3
Serial status register 3 SSR3 R/(W)
*
2
H'84 H'FDD4
Receive data register 3 RDR3 R H'00 H'FDD5
Smart card mode register 3 SCMR3 R/W H'F2 H'FDD6
4 Serial mode register 4 SMR4 R/W H'00 H'FDD8
Bit rate register 4 BRR4 R/W H'FF H'FDD9
Serial control register 4 SCR4 R/W H'00 H'FDDA
Transmit data register 4 TDR4 R/W H'FF H'FDDB
Serial status register 4 SSR4 R/(W)
*
2
H'84 H'FDDC
Receive data register 4 RDR4 R H'00 H'FDDD
Smart card mode register 4 SCMR4 R/W H'F2 H'FDDE
All Module stop control register B MSTPCRB R/W H'FF H'FDE9
Module stop control register C MSTPCRC R/W H'FF H'FDEA
Notes: 1. Lower 16 bits of the address.
2. Only 0 can be written, for flag clearing.
3. Some of the SCI registers are allocated to the same addresses as other registers. The
IICE bit of the serial control register X (SCRX) selects the respective registers.