Datasheet

Section 16 Serial Communication Interface (SCI, IrDA)
(The H8S/2695 is not equipped with an IrDA function)
R01UH0166EJ0600 Rev. 6.00 Page 757 of 1434
Mar 02, 2011
H8S/2633 Group, H8S/2633 F-ZTAT
TM
,
H8S/2633R F-ZTAT
TM
, H8S/2695
16.3 Operation
16.3.1 Overview
The SCI can carry out serial communication in two modes: asynchronous mode in which
synchronization is achieved character by character, and clocked synchronous mode in which
synchronization is achieved with clock pulses.
Selection of asynchronous or clocked synchronous mode and the transmission format is made
using SMR as shown in table 16.8. The SCI clock is determined by a combination of the C/A bit
in SMR and the CKE1 and CKE0 bits in SCR, as shown in table 16.9.
Asynchronous Mode
Data length: Choice of 7 or 8 bits
Choice of parity addition, multiprocessor bit addition, and addition of 1 or 2 stop bits (the
combination of these parameters determines the transfer format and character length)
Detection of framing, parity, and overrun errors, and breaks, during reception
Choice of internal or external clock as SCI clock source
When internal clock is selected:
The SCI operates on the baud rate generator clock and a clock with the same frequency as
the bit rate can be output
When external clock is selected:
A clock with a frequency of 16 times the bit rate must be input (the on-chip baud rate
generator is not used)
Clocked Synchronous Mode
Transfer format: Fixed 8-bit data
Detection of overrun errors during reception
Choice of internal or external clock as SCI clock source
When internal clock is selected:
The SCI operates on the baud rate generator clock and a serial clock is output off-chip
When external clock is selected:
The on-chip baud rate generator is not used, and the SCI operates on the input serial clock