Datasheet
Section 16 Serial Communication Interface (SCI, IrDA)
(The H8S/2695 is not equipped with an IrDA function)
R01UH0166EJ0600 Rev. 6.00 Page 779 of 1434
Mar 02, 2011
H8S/2633 Group, H8S/2633 F-ZTAT
TM
,
H8S/2633R F-ZTAT
TM
, H8S/2695
Data Transfer Format
A fixed 8-bit data format is used.
No parity or multiprocessor bits are added.
Clock
Either an internal clock generated by the on-chip baud rate generator or an external serial clock
input at the SCK pin can be selected, according to the setting of the C/A bit in SMR and the CKE1
and CKE0 bits in SCR. For details of SCI clock source selection, see table 16.9.
When the SCI is operated on an internal clock, the serial clock is output from the SCK pin.
Eight serial clock pulses are output in the transfer of one character, and when no transfer is
performed the clock is fixed high. When only receive operations are performed, however, the
serial clock is output until an overrun error occurs or the RE bit is cleared to 0. If you want to
perform receive operations in units of one character, you should select an external clock as the
clock source.