Section 16 Serial Communication Interface (SCI, IrDA)
(The H8S/2695 is not equipped with an IrDA function)
R01UH0166EJ0600 Rev. 6.00 Page 783 of 1434
Mar 02, 2011
H8S/2633 Group, H8S/2633 F-ZTAT
TM
,
H8S/2633R F-ZTAT
TM
, H8S/2695
Figure 16.17 shows an example of SCI operation in transmission.
Transfer direction
Bit 0
Serial data
Serial clock
1 frame
TDRE
TEND
Bit 1 Bit 7 Bit 0 Bit 1 Bit 7Bit 6
Data written to TDR
and TDRE flag
cleared to 0 in TXI
interrupt service routine
TEI interrupt
request generated
TXI interrupt
request generated
TXI interrupt
request generated
Figure 16.17 Example of SCI Operation in Transmission
Serial data reception (clocked synchronous mode): Figure 16.18 shows a sample flowchart for
serial reception.
The following procedure should be used for serial data reception.
When changing the operating mode from asynchronous to clocked synchronous, be sure to check
that the ORER, PER, and FER flags are all cleared to 0.
The RDRF flag will not be set if the FER or PER flag is set to 1, and neither transmit nor receive
operations will be possible.