17.3 Operation
17.3.1 Overview
The main functions of the Smart Card interface are as follows.
• One frame consists of 8-bit data plus a parity bit.
• In transmission, a guard time of at least 2 etu (1 etu in the block transfer mode) is left between
the end of the parity bit and the start of the next frame.
• If a parity error is detected during reception, a low error signal level is output for one etu
period, 10.5 etu after the start bit.
• If the error signal is sampled during transmission, the same data is transmitted automatically
after the elapse of 2 etu or longer. (except in block transfer mode)
• Only asynchronous communication is supported; there is no clocked synchronous
communication function.