Section 19 Power-On Reset and Low-Voltage Detection Circuits (Optional)
Rev. 4.00 Mar. 15, 2006 Page 412 of 556
REJ09B0026-0400
Procedures for Clearing Settings when Using LVDR and LVDI:
To operate or release the low-voltage detection circuit normally, follow the procedure described
below. Figure 19.5 shows the timing for the operation and release of the low-voltage detection
circuit.
1. To operate the low-voltage detection circuit, set the LVDE bit in LVDCR to 1.
2. Wait for 50 ยตs (t
LVDON
) until the reference voltage and the low-voltage-detection power supply
have stabilized by a software timer, etc. Then, clear the LVDDF and LVDUF bits in LVDSR
to 0 and set the LVDRE, LVDDE, and LVDUE bits in LVDCR to 1, as required.
3. To release the low-voltage detection circuit, start by clearing all of the LVDRE, LVDDE, and
LVDUE bits to 0. Then clear the LVDE bit to 0. The LVDE bit must not be cleared to 0 at the
same timing as the LVDRE, LVDDE, and LVDUE bits because incorrect operation may occur.
LVDRE
LVDDE
LVDUE
t
LVDON
LVDE
Figure 19.5 Timing for Operation/Release of Low-Voltage Detection Circuit