Datasheet
Section 22 Electrical Characteristics
Rev. 4.00 Mar. 15, 2006 Page 454 of 556
REJ09B0026-0400
Table 22.5 Controller Area Network for Tiny (TinyCAN) Timing
V
CC
= 3.0 to 5.5 V, V
SS
= 0.0 V, T
a
= –20 to +75°C (regular specifications) or T
a
= –40 to +85°C
(wide-range specifications), unless otherwise indicated.
Values
Item Symbol
Applicable
Pins
Test
Condition
Min. Typ. Max. Unit
Reference
Figure
Transmit
data delay
time*
t
HTXD
HTXD — — 50 ns Figure 22.6
Receive
data setup
time*
t
HRXS
HRXD 50 — — ns
Receive
data hold
time*
t
HRXH
HRXD 50 — — ns
Note: * Although the TinyCAN input/output signal is asynchronous, its state is determined to
have changed at the rising-edge (two clock cycles) of the CK clock shown in figure
22.6.