Datasheet
Section 6 Power-Down Modes
Rev. 2.00 Sep. 23, 2005 Page 72 of 444
REJ09B0068-0200
6.1.2 System Control Register 2 (SYSCR2)
SYSCR2 controls the power-down modes, as well as SYSCR1.
Bit Bit Name
Initial
Value R/W Description
7 SMSEL 0 R/W Sleep Mode Selection
This bit selects the transition mode after the execution
of the SLEEP instruction, as well as the SSBY bit in
SYSCR1.
For details, see table 6.2.
6 0 Reserved
This bit is always read as 0.
5 DTON 0 R/W Direct Transfer On Flag
This bit selects the transition mode after the execution
of the SLEEP instruction, as well as the SSBY bit in
SYSCR1.
For details, see table 6.2.
4
3
2
MA2
MA1
MA0
0
0
0
R/W
R/W
R/W
Active Mode Clock Select 2 to 0
These bits select the operating clock frequency in active
and sleep modes. The operating clock frequency
changes to the set frequency after the SLEEP
instruction is executed.
0XX: φ
OSC
100: φ
OSC
/8
101: φ
OSC
/16
110: φ
OSC
/32
111: φ
OSC
/64
1, 0 All 0 Reserved
These bits are always read as 0.
[Legend]
X: Don't care.