Datasheet
Section 12 Timer Z
Rev. 2.00 Sep. 23, 2005 Page 179 of 444
REJ09B0068-0200
12.4.2 Waveform Output by Compare Match
Timer Z can perform 0, 1, or toggle output from the corresponding FTIOA, FTIOB, FTIOC, or
FTIOD output pin using compare match A, B, C, or D.
Figure 12.12 shows an example of the setting procedure for waveform output by compare match.
[1] Select 0 output, 1 output, or toggle
output as a compare much output, by
means of TIOR. The initial values set in
TOCR are output unit the first compare
match occurs.
[2] Set the timing for compare match
generation in GRA/GRB/GRC/GRD.
[3] Enable or disable the timer output by
TOER.
[4] Set the STR bit in TSTR to 1 to start the
TCNT count operation.
[1]
Output selection
Select waveform output mode
[2]
Set output timing
[3]
Enable waveform output
[4]
Start count operation
<Waveform output>
Figure 12.12 Example of Setting Procedure for Waveform Output by Compare Match