Datasheet
Section 22 Electrical Characteristics
Rev. 3.00 Sep. 10, 2007 Page 428 of 528
REJ09B0216-0300
Table 22.4 I
2
C Bus Interface Timing
V
CC
= 4.5 to 5.5 V, V
SS
= 0.0 V, T
a
= -20 to +75°C/-40 to +85°C, unless otherwise indicated.
Values
Item Symbol
Test
Condition Min. Typ. Max. Unit
Reference
Figure
SCL input cycle time t
SCL
12t
cyc
+ 600 — — ns Figure 22.4
SCL input high width t
SCLH
3t
cyc
+ 300 — — ns
SCL input low width t
SCLL
5t
cyc
+ 300 — — ns
SCL and SDA input
fall time
t
Sf
— — 300 ns
SCL and SDA input
spike pulse removal
time
t
SP
— — 1t
cyc
ns
SDA input bus-free
time
t
BUF
5t
cyc
— — ns
Start condition input
hold time
t
STAH
3t
cyc
— — ns
Repeated start
condition input setup
time
t
STAS
3t
cyc
— — ns
Setup time for stop
condition input
t
STOS
3t
cyc
— — ns
Data-input setup time t
SDAS
1t
cyc
+20 — — ns
Data-input hold time t
SDAH
0 — — ns
Capacitive load of
SCL and SDA
c
b
0 — 400 pF
SCL and SDA output
fall time
t
Sf
— — 250 ns