Datasheet

Section 17 I
2
C Bus Interface 2 (IIC2)
Rev. 3.00 Sep. 10, 2007 Page 342 of 528
REJ09B0216-0300
Bit Bit Name
Initial
Value
R/W Description
3 STOP 0 R/W Stop Condition Detection Flag
[Setting conditions]
In master mode, when a stop condition is detected
after frame transfer
In slave mode, when a stop condition is detected after
the following events:
A general call is invoked
A start condition is detected
The first byte in the slave address matches the
address set in the SAR
[Clearing condition]
When 0 is written in STOP after reading STOP = 1
2 AL/OVE 0 R/W Arbitration Lost Flag/Overrun Error Flag
This flag indicates that arbitration was lost in master
mode with the I
2
C bus format and that the final bit has
been received while RDRF = 1 with the clock
synchronous format.
When two or more master devices attempt to seize the
bus at nearly the same time, if the I
2
C bus interface
detects data differing from the data it sent, it sets AL to 1
to indicate that the bus has been taken by another
master.
[Setting conditions]
If the internal SDA and SDA pin disagree at the rise of
SCL in master transmit mode
When the SDA pin outputs high in master mode while
a start condition is detected
When the final bit is received with the clock
synchronous format while RDRF = 1
[Clearing condition]
When 0 is written in AL/OVE after reading AL/OVE=1