Datasheet
Section 17 I
2
C Bus Interface 2 (IIC2) 
Rev. 3.00 Sep. 10, 2007 Page 342 of 528 
REJ09B0216-0300   
Bit Bit Name 
Initial 
Value 
R/W Description 
3  STOP  0  R/W  Stop Condition Detection Flag 
[Setting conditions] 
•  In master mode, when a stop condition is detected 
after frame transfer 
•  In slave mode, when a stop condition is detected after 
the following events: 
  A general call is invoked 
  A start condition is detected 
  The first byte in the slave address matches the 
address set in the SAR 
[Clearing condition] 
•  When 0 is written in STOP after reading STOP = 1 
2  AL/OVE  0  R/W  Arbitration Lost Flag/Overrun Error Flag 
This flag indicates that arbitration was lost in master 
mode with the I
2
C bus format and that the final bit has 
been received while RDRF = 1 with the clock 
synchronous format. 
When two or more master devices attempt to seize the 
bus at nearly the same time, if the I
2
C bus interface 
detects data differing from the data it sent, it sets AL to 1 
to indicate that the bus has been taken by another 
master. 
[Setting conditions] 
•  If the internal SDA and SDA pin disagree at the rise of 
SCL in master transmit mode 
•  When the SDA pin outputs high in master mode while 
a start condition is detected 
•  When the final bit is received with the clock 
synchronous format while RDRF = 1 
[Clearing condition] 
•  When 0 is written in AL/OVE after reading AL/OVE=1 