Datasheet
Section 22 Electrical Characteristics
Rev. 3.00 Sep. 10, 2007 Page 418 of 528
REJ09B0216-0300
(3) Analog Power Supply Voltage and A/D Converter Accuracy Guaranteed Range
4.0
20.0
4.5 5.5 AV
CC
(V)
φ (MHz)
• V
CC
= 4.5 to 5.5 V
• Active mode
• Sleep mode
(4) Range of Power Supply Voltage and Oscillation Frequency when Low-Voltage
Detection Circuit is Used
Operation guaranteed range
Operation guaranteed range except
A/D conversion accuracy
20.0
16.0
4.0
3.0 4.5 5.5
Vcc (V)
φosc (MHz)