Section 14 Timer RD
Rev. 1.50 Sep. 18, 2007 Page 314 of 584
REJ09B0240-0150
(2) Input Capture Signal Timing
Input capture on the rising edge, falling edge, or both edges can be selected through settings in
TRDIOR. Figure 14.21 shows the timing when the rising edge is selected.
TRDCNT
Input capture signal
Input capture input
GR
N
N
φ
Figure 14.21 Input Capture Signal Timing