Datasheet

Section 12 Timer W
Rev. 3.00 Sep. 14, 2006 Page 180 of 408
REJ09B0105-0300
TCNT value
GRA
H'0000
FTIOB
Time
GRB
Duty 100%
Write to GRB
TCNT value
GRA
H'0000
FTIOB
Time
GRB
Duty 0%
Write to GRB
Write to GRB
Output does not change when cycle register
and duty register compare matches occur
simultaneously.
TCNT value
GRA
H'0000
FTIOB
Time
GRB
Duty 0%
Write to GRB
Write to GRB
Output does not change when cycle register
and duty register compare matches occur
simultaneously.
Duty 100%
Write to GRB
Write to GRB
Write to GRB
Figure 12.13 PWM Mode Example
(TOB, TOC, and TOD = 1: Initial Output Values are Set to 1)