Datasheet

Section 12 Timer W
Rev. 3.00 Sep. 14, 2006 Page 184 of 408
REJ09B0105-0300
12.5.5 Buffer Operation Timing
Figures 12.19 and 12.20 show the buffer operation timing.
GRC, GRD
Compare
match signal
TCNT
φ
GRA, GRB
N
N+1
M
M
Figure 12.19 Buffer Operation Timing (Compare Match)
GRA, GRB
TCNT
Input capture
signal
φ
GRC, GRD
N
M
M N+1
N
N N+1
Figure 12.20 Buffer Operation Timing (Input Capture)