Datasheet

Section 15 I
2
C Bus Interface 2 (IIC2)
Rev. 3.00 Sep. 14, 2006 Page 271 of 408
REJ09B0105-0300
15.6 Bit Synchronous Circuit
In master mode, this module has a possibility that high level period may be short in the two states
described below.
When SCL is driven to low by the slave device
When the rising speed of SCL is lowered by the load of the SCL line (load capacitance or pull-
up resistance)
Therefore, it monitors SCL and communicates by bit with synchronization.
Figure 15.21 shows the timing of the bit synchronous circuit and table 15.4 shows the time when
SCL output changes from low to Hi-Z then SCL is monitored.
SCL
V
IH
SCL monitor
timing reference
clock
Internal SCL
Figure 15.21 Timing of Bit Synchronous Circuit
Table 15.4 Time for Monitoring SCL
CKS3 CKS2 Time for Monitoring SCL
0 7.5 tcyc 0
1 19.5 tcyc
0 17.5 tcyc 1
1 41.5 tcyc