Datasheet

Table Of Contents
Section 6 Power-Down Modes
Rev. 2.00 Jul. 04, 2007 Page 126 of 692
REJ09B0309-0200
t
cyc
t
subcyc
t
cyc
t
subcyc
t
cyc
t
subcyc
t
cyc
t
subcyc
Capture possible: case 1
Capture possible: case 2
Capture possible: case 3
Capture not possible
φ or φ
SUB
Operating mode
Active (high-speed, medium-speed)
mode or subactive mode
Standby mode or
watch mode
Wait for osc-
illation
stabilization
Active (high-speed, medium-speed)
mode or subactive mode
External input signal
Interrupt by different signal
Figure 6.3 External Input Signal Capture when Signal Changes before/after Standby Mode
or Watch Mode
(4) Input Pins to which these Notes Apply
NMI, IRQ0, IRQ1, IRQ3, IRQ4, IRQAEC, WKP0
to WKP7, TMIC, TMIF, TMIG, ADTRG,
TIOCA1, TIOCB1, TIOCA2, and TIOCB2.