Datasheet

Table Of Contents
Section 12 Timer F
Rev. 2.00 Jul. 04, 2007 Page 247 of 692
REJ09B0309-0200
12.5 Timer F Operating States
The timer F operating states are shown in table 12.2.
Table 12.2 Timer F Operating States
Operating
Mode
Reset
Active
Sleep
Watch
Sub-active Sub-sleep
Standby
Module
Standby
TCF Reset Functioning* Functioning* Functioning/
Halted*
Functioning/
Halted*
Functioning/
Halted*
Halted Halted
OCRF Reset Functioning Retained Retained Functioning Retained Retained Retained
TCRF Reset Functioning Retained Retained Functioning Retained Retained Retained
TCSRF Reset Functioning Retained Retained Functioning Retained Retained Retained
Note: * When φ
W
/4 is selected as the TCF input clock in active mode or sleep mode, since the
system clock and internal clock are mutually asynchronous, synchronization is
maintained by a synchronization circuit. This results in a maximum count cycle error of
1/φ (s). When the counter is operated in subactive mode, watch mode, or subsleep
mode, φ
W
/4 must be selected as the internal clock. The counter will not operate if any