Section 17 Serial Communications Interface 3 (SCI3, IrDA)
Rev. 2.00 Jul. 04, 2007 Page 395 of 692
REJ09B0309-0200
17.5.5 Simultaneous Serial Data Transmission and Reception
Figure 17.14 shows a sample flowchart for simultaneous serial transmit and receive operations.
The following procedure should be used for simultaneous serial data transmit and receive
operations. To switch from transmit mode to simultaneous transmit and receive mode, after
checking that the SCI3 has finished transmission and the TDRE and TEND flags are set to 1, clear
TE to 0. Then simultaneously set TE and RE to 1 with a single instruction. To switch from receive
mode to simultaneous transmit and receive mode, after checking that the SCI3 has finished
reception, clear RE to 0. Then after checking that the RDRF and receive error flags (OER, FER,
and PER) are cleared to 0, simultaneously set TE and RE to 1 with a single instruction.
Yes
End
No
Start transmission/reception
[3]
Overrun error processing
[4]
Read receive data in RDR
Yes
No
OER = 1
Data transmission/reception
continued?
[1]
Read TDRE flag in SSR
Set SPC3 bit in SPCR or SPCR2 to 1
No
Yes
TDRE = 1
Write transmit data to TDR
No
Yes
RDRF = 1
Read OER flag in SSR
[2]
Read RDRF flag in SSR
Clear TE and RE bits in SCR to 0
[1] Read SSR and check that the TDRE
flag is set to 1, then write transmit
data to TDR.
When data is written to TDR, the
TDRE flag is automatically cleared to
0.
[2] Read SSR and check that the RDRF
flag is set to 1, then read the receive
data in RDR.
When data is read from RDR, the
RDRF flag is automatically cleared to
0.
[3] To continue serial transmission/
reception, before the MSB (bit 7) of
the current frame is received, finish
reading the RDRF flag, reading RDR.
Also, before the MSB (bit 7) of the
current frame is transmitted, read 1
from the TDRE flag to confirm that
writing is possible. Then write data to
TDR.
When data is written to TDR, the
TDRE flag is automatically cleared to
0. When data is read from RDR, the
RDRF flag is automatically cleared to
0.
[4] If an overrun error occurs, read the
OER flag in SSR, and after
performing the appropriate error
processing, clear the OER flag to 0.
Transmission/reception cannot be
resumed if the OER flag is set to 1.
For overrun error processing, see
figure 17.13.
Figure 17.14 Sample Flowchart of Simultaneous Serial Transmit and Receive Operations
(Clock Synchronous Mode)