Datasheet

Table Of Contents
Section 21 LCD Controller/Driver
Rev. 2.00 Jul. 04, 2007 Page 462 of 692
REJ09B0309-0200
21.3.3 LCD Control Register 2 (LCR2)
LCR2 controls switching between the A waveform and B waveform, selection of the step-up clock
for the 3-V constant-voltage circuit, connection with the LCD power-supply split resistor, and
turning on or off 3-V constant-voltage power supply.
Bit Bit Name
Initial
Value
R/W Description
7 LCDAB 0 R/W A Waveform/B Waveform Switching Control
Specifies whether the A waveform or B waveform is used
as the LCD drive waveform.
0: Drive using A waveform
1: Drive using B waveform
6 HCKS 0 R/W Step-Up Clock Selection for 3-V Constant-Voltage Power
Supply Circuit
Selects a step-up clock for use in the 3-V constant-
voltage power supply circuit. The step-up clock is
obtained by dividing the clock selected by the CKS3 to
CKS0 bits in LCR into 4 or 8.
0: Divided into 4
1: Divided into 8
5 CHG 0 R/W Connection Control of LCD Power-Supply Split Resistor
Selects whether an LCD power-supply split resistor is
disconnected or connected from or to LCD drive power
supply.
0: Disconnected
1: Connected
4 SUPS 0 R/W 3-V Constant-Voltage Power Supply Control
Can be used to turn off the 3-V constant-voltage power
supply when LCD display is not required in power-down
mode, or when an external power supply is used. When
the BGRSTPN bit in BGRMR is cleared to 0 or in standby
mode, the 3-V constant-voltage power supply is turned off
regardless of the setting of this bit.
0: 3-V constant-voltage power supply is turned off
1: 3-V constant-voltage power supply is turned on
3 to 0 1 Reserved
These bits are always read as 1 and cannot be modified.