Table 5.2 Internal State in Each Operating Mode
Active Mode Sleep Mode
Function
High-
Speed
Medium-
Speed
High-
Speed
Medium-
Speed
Watch
Mode
Subactive
Mode
Subsleep
Mode
Standby
Mode
System clock oscillator Functions Functions Functions Functions Halted Halted Halted Halted
Subclock oscillator Functions Functions Functions Functions Functions Functions Functions Functions
CPU Instructions Functions Functions Halted Halted Halted Functions Halted Halted
operations RAM Retained Retained Retained Retained Retained
Registers
I/O ports Retained
*
1
External IRQ
0
Functions Functions Functions Functions Functions Functions Functions Functions
interrupts IRQ
1
Retained
*
6
IRQ
2
Retained
*
6
IRQ
3
IRQ
4
WKP
0
Functions Functions Functions Functions Functions Functions Functions Functions
WKP
1
WKP
2
WKP
3
WKP
4
WKP
5
WKP
6
WKP
7
Peripheral Timer A Functions Functions Functions Functions Functions
*
5
Functions
*
5
Functions
*
5
Retained
functions Asynchro-
nous counter
Functions
*
8
Functions Functions Functions
*
8
Timer C Retained Functions/
Retained
*
2
Functions/
Retained
*
2
Retained
WDT Functions/
Retained
*
7
Retained
Timer G,
Timer F
Functions/
Retained
*
9
Functions/
Retained
*
2
Functions/
Retained
*
2
SCI1 Retained Functions/
Retained
*
9
Functions/
Retained
*
9
Retained
SCI3-1,
SCI3-2
Reset Functions/
Retained
*
3
Functions/
Retained
*
3
Reset
PWM Retained Retained Retained Retained
A/D
converter
Retained Retained Retained Retained
LCD Functions/
Retained
*
4
Functions/
Retained
*
4
Functions/
Retained
*
4
Retained
Notes: 1. Register contents are retained, but output is high-impedance state.
2. Functions if an external clock or the
φ
W
/4 internal clock is selected; otherwise halted and retained.
3. Functions if
φ
W
/2 is selected as the internal clock; otherwise halted and retained.
4. Functions if
φ
W
or φ
W
/2 or φ
W
/4 is selected as the operating clock; otherwise halted and retained.
5. Functions if the timekeeping time-base function is selected.
6. External interrupt requests are ignored. Interrupt request register contents are not altered.
7. Functions if
φ
W
/32 is selected as the internal clock; otherwise halted and retained.