To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology Corporation, and Renesas Electronics Corporation took over all the business of both companies. Therefore, although the old company name remains in this document, it is a valid Renesas Electronics document. We appreciate your understanding. Renesas Electronics website: http://www.renesas.
Notice 1. 2. 3. 4. 5. 6. 7. All information included in this document is current as of the date this document is issued. Such information, however, is subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm the latest product information with a Renesas Electronics sales office.
To all our customers Regarding the change of names mentioned in the document, such as Hitachi Electric and Hitachi XX, to Renesas Technology Corp. The semiconductor operations of Mitsubishi Electric and Hitachi were transferred to Renesas Technology Corporation on April 1st 2003. These operations include microcomputer, logic, analog and discrete devices, and memory chips other than DRAMs (flash memory, SRAMs etc.) Accordingly, although Hitachi, Hitachi, Ltd.
User’s Manual H8S/2128 Series, H8/3577 DP-64S User System Interface Cable (HS2128ECS61H) for E6000 Emulator User’s Manual Rev.0.1 2000.
IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. User System Interface Cable: Throughout this document, the term "user system interface cable" shall be defined as the following product produced only by Hitachi, Ltd. excluding all subsidiary products.
LIMITED WARRANTY Hitachi warrants its user system interface cables to be manufactured in accordance with published specifications and free from defects in material and/or workmanship. Hitachi will repair or replace any user system interface cables determined to be defective in material and/or workmanship. User system interface cables are wearing parts which Hitachi will not repair or replace if damaged and/or worn through use.
State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may have other rights which may vary from state to state.
SAFETY PAGE READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. DEFINITION OF SIGNAL WORDS This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance. 2. Always switch OFF the E6000 emulator and user system before connecting or disconnecting any CABLES or PARTS. 3.
Cautions 1. Hitachi neither warrants nor grants licenses of any rights of Hitachi’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Hitachi bears no responsibility for problems that may arise with third party’s rights, including intellectual property rights, in connection with use of the information contained in this document. 2. Products and product specifications may be subject to change without notice.
Preface Thank you for purchasing this user system interface cable (HS2128ECS61H) for the Hitachi’s original microcomputers H8S/2128 series and H8/3577 series. The HS2128ECS61H is a user system interface cable that connects an H8S/2148 series E6000 emulator (HS2148EPI61H; hereinafter referred to as the emulator) to the IC socket for a DP-64S package for the H8S/2128 series and H8/3577 series MCUs on the user system.
Contents Section 1 Configuration ....................................................................................1 Section 2 Connection Procedures ......................................................................3 2.1 2.2 2.3 2.4 Connecting User System Interface Cable to Emulator Station ..........................................3 Connecting User System Interface Cable to User System .................................................5 2.2.1 Installing IC Socket .................................
Section 1 Configuration CAUTION Use an IC83-64075-GS4 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the DP-64S package IC socket on the user system. Figure 1 shows the configuration of the HS2128ECS61H user system interface cable for the DP-64S package.
Table 1 lists the HS2128ECS61H components. Please make sure you have all of these components when unpacking. Table 1 HS2128ECS61H Components No.
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part.
Figure 2 Connecting User System Interface Cable to Emulator Station 4
2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST.
2.2.1 Installing IC Socket Prepare an IC socket (commercially available) for the DP-64S package and mount it on the user system. Recommended IC socket: IC83-64075-GS4 (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) 2.2.2 Inserting Cable Head CAUTION Check the location of pin 1 before inserting.
2.2.3 Fastening Cable Body Connect the cable body to the cable head. Cable body Removing Push the remove jig.
2.3 Dimensions for User System Interface Cable Head 21.6 78.7 10.6 57.7 The dimensions for the user system interface cable head are shown in figure 5. 26.0 63.5 Unit: mm Tolerance: ±0.
2.4 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 6. 21.5 IC socket (for protection) (IC83-64075-GS4 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) 12.0 Cable head User system Unit: mm IC socket Tolerance: ±0.5 mm (IC83-64075-GS4 manufactured by YAMAICHI ELECTRONICS Co., Ltd.
Section 3 Verifying Operation 1. When using the H8S/2148 series E6000 emulator (HS2148EPI61H), turn on the emulator according to the procedures described in the H8S Series E6000 Emulator User's Manual (HS2000EPI61HE). 2. Verify the user system interface cable connections by accessing ports and checking the bus states of the pins. If an error is detected, recheck the soldered IC socket and the location of pin 1. 3.
Section 4 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. This user system interface cable is specifically designed for the HS2148EPI60H emulator. Do not use this cable with any other emulator station. 3. To prevent breaking of wires in the cable body, do not place heavy or sharp metal objects on the user system interface cable. 4.
5. The JP1 jumper connector is used for testing. Do not remove the inserted jumper pin.