Emulation Probe User's Manual
M30850T2-EPB User’s Manual  3. Usage (How to Use the Emulator Debugger) 
REJ10J1005-0200 Rev.2.00 April 1, 2007 
(2) Program execution 
1. Resetting the user program 
2. Executing the user program 
3. Stopping the user program 
4. Program window screen after the user program has stopped 
RESET 
Resets the program. 
GO 
Executes the program from the current PC position. 
STEP 
Single-steps the program, stepping subroutines. 
OVER 
Single-steps the program, skipping over subroutines. 
RETURN 
Executes the program up to the high-order subroutine. 
STOP 
Stops the program. 
Program window screen 
The program position at which the program has stopped is 
identified by the yellow background color. 
  Page 59 of 98 